Features :
1 .Automatic electric potential tracking and correcting software to ensure the stable performance
2 .Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement .
3 .Real-time diagnostic system working status
4 .Waste liquid automatic detection and alarming
5 .Automatic calibration and two-point correction to adjust slope and intercept .
6 .Wave flushing method and direct flushing pipe method to avoid block and crossed contamination
7 .Power failure protection for data storage up to 20000 results
8 .Minimum consumption ,reduce consumable cost
9 .Rapid test speed of 80 tests per hour
10 .Option :Sample tray
Model | Measuring Range | Resolution | Measuring Precision |
K+ | 0.5-20.0mmol/L | 0.01mmol/L | ≤1.0% |
Na+ | 15-200mmol/L | 0.1mmol/L | ≤1.0% |
Cl+ | 15-200mmol/L | 0.1mmol/L | ≤1.0% |
Ca2+ | 0.1-6.0mmol/L | 0.01mmol/L | ≤1.0% |
Li+ | 0.1-5.0mmol/L | 0.01mmol/L | ≤2.0% |
pH | 4-9pH | 0.01pH | ≤0.5% |
TCO2 | 2.0-70.0mmol/L | 0.1mmol/L | ≤3.0% |
Item | BKE Series | |
Sample | Serum,plasma,whole blood,cerebrospinal fluid and dilute urine | |
Mesauring Speed | ≤25s | |
Analysis Method | Ion selective electrode(ISE) | |
Sample Volume | 60-300μl(3 parameters to 11 parameters) | |
Sample Position | 35 Positions(including 1 QC) | |
Storage | Up to 10,000 test results | |
Printer | Built-in thermal printer | |
Interface | RS232 port | |
Working Conditions | Power Supply | AC220V±10% 50/60Hz;110V±10% 60Hz;120W |
Temperature | 10-30°c | |
Relative Humidity | ≤80% | |
Atmospheric Pressure | (86-106)Kpa | |
Package Size(W*D*H) | 500*400*710mm | |
Gross Weight | 15kg |
Features :
1 .Automatic electric potential tracking and correcting software to ensure the stable performance
2 .Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement .
3 .Real-time diagnostic system working status
4 .Waste liquid automatic detection and alarming
5 .Automatic calibration and two-point correction to adjust slope and intercept .
6 .Wave flushing method and direct flushing pipe method to avoid block and crossed contamination
7 .Power failure protection for data storage up to 20000 results
8 .Minimum consumption ,reduce consumable cost
9 .Rapid test speed of 80 tests per hour
10 .Option :Sample tray
Model | Measuring Range | Resolution | Measuring Precision |
K+ | 0.5-20.0mmol/L | 0.01mmol/L | ≤1.0% |
Na+ | 15-200mmol/L | 0.1mmol/L | ≤1.0% |
Cl+ | 15-200mmol/L | 0.1mmol/L | ≤1.0% |
Ca2+ | 0.1-6.0mmol/L | 0.01mmol/L | ≤1.0% |
Li+ | 0.1-5.0mmol/L | 0.01mmol/L | ≤2.0% |
pH | 4-9pH | 0.01pH | ≤0.5% |
TCO2 | 2.0-70.0mmol/L | 0.1mmol/L | ≤3.0% |
Item | BKE Series | |
Sample | Serum,plasma,whole blood,cerebrospinal fluid and dilute urine | |
Mesauring Speed | ≤25s | |
Analysis Method | Ion selective electrode(ISE) | |
Sample Volume | 60-300μl(3 parameters to 11 parameters) | |
Sample Position | 35 Positions(including 1 QC) | |
Storage | Up to 10,000 test results | |
Printer | Built-in thermal printer | |
Interface | RS232 port | |
Working Conditions | Power Supply | AC220V±10% 50/60Hz;110V±10% 60Hz;120W |
Temperature | 10-30°c | |
Relative Humidity | ≤80% | |
Atmospheric Pressure | (86-106)Kpa | |
Package Size(W*D*H) | 500*400*710mm | |
Gross Weight | 15kg |