ECG Machine
Digital EEG/ECG/EKG/EMG/VCG
CE, ISO13485
All The People
Medtrue
Digital ECG Machine
CE/ISO Approved Hot Sale Cheap Medical Six 6-Channel Interpretive ECG Machine (MT01008022)
Features
| 3/4(3-6)/6 channel printout format | ||
| 5.1 inch 320x240 LCD to display ECG waveform, setting menu and operating status | ||
| Rhythm lead with R-R interval histogram and trend graph | ||
| Automatic measurement and interpretation of standard ECG parameters | ||
| Built in RS232/USB interface supporting data transmission to PC | ||
| 128 exams in memory for recall and duplication | ||
| Able to enter patient into of ID, sex, age & weight | ||
| Two way for data communcation with HIS in format of XML, JPG, PDF, etc | ||
| Optional ECG viewer software for further data management | ||
| Paper size: 112mmx20m, roll type |
| Lead | Standard 12 lead | A/D Converter | 12 bit |
| Input Circuit | Isolated:Protection aganinst pace making and defibrillation | Recording paper | Roll paper 50mmx20m(30m) |
| Input Impedance | ≥50MΩ | Operation Mode | AUTO/MAN UAL |
| Input Circuit Current | ≤50nA | Printer | Thermal array printer |
| Calibrating Voltage | 1mA±3% | ||
| Skin Voltage Tolerance | ±300mV | Baseline control | Automatic position |
| Sensitivity | 5,10,20mm/mv | Rhythm Lead | Standard 12 lead |
| Filter | AC:50Hz(-2dB):emg:35~45Hz(-3dB) | Lead Change | Automatic/Manual |
| Papler Speed | 25,50mm/s±3% | External Singal | 10mm/mV±5%;single ended≥100KΩ |
| Time Constant | ≥3.2s(0,20%) | ECG Output | 0.5V/m±5%;single ended≤100Ω |
| Noise Level | ≤15mVp-p | Safety Level | Class1,Type CF |
| Frequency Response | 0.05~150Hz(-3dB) | Power Requirements | AC:220V,50Hz/110V,60Hz |
| CMRR | ≥100dB | Package | 760x550x450mm(4sets);240x450x370mm(1set) |
| Sampling Rate | 1ms | Weight | 3.5kg |
Standard Accessory
Patient Cable:1pc
Paper shaft:1pc
Limb Electrode:4pcs/set
Recording paper:1 roll
Chest Electrodes:6pcs/set
Fuse:3pcsPower Cable:1pc
Built in Battery:1pc
Ground Cable:1pc
Operation Manual:1 copy
CE/ISO Approved Hot Sale Cheap Medical Six 6-Channel Interpretive ECG Machine (MT01008022)
Features
| 3/4(3-6)/6 channel printout format | ||
| 5.1 inch 320x240 LCD to display ECG waveform, setting menu and operating status | ||
| Rhythm lead with R-R interval histogram and trend graph | ||
| Automatic measurement and interpretation of standard ECG parameters | ||
| Built in RS232/USB interface supporting data transmission to PC | ||
| 128 exams in memory for recall and duplication | ||
| Able to enter patient into of ID, sex, age & weight | ||
| Two way for data communcation with HIS in format of XML, JPG, PDF, etc | ||
| Optional ECG viewer software for further data management | ||
| Paper size: 112mmx20m, roll type |
| Lead | Standard 12 lead | A/D Converter | 12 bit |
| Input Circuit | Isolated:Protection aganinst pace making and defibrillation | Recording paper | Roll paper 50mmx20m(30m) |
| Input Impedance | ≥50MΩ | Operation Mode | AUTO/MAN UAL |
| Input Circuit Current | ≤50nA | Printer | Thermal array printer |
| Calibrating Voltage | 1mA±3% | ||
| Skin Voltage Tolerance | ±300mV | Baseline control | Automatic position |
| Sensitivity | 5,10,20mm/mv | Rhythm Lead | Standard 12 lead |
| Filter | AC:50Hz(-2dB):emg:35~45Hz(-3dB) | Lead Change | Automatic/Manual |
| Papler Speed | 25,50mm/s±3% | External Singal | 10mm/mV±5%;single ended≥100KΩ |
| Time Constant | ≥3.2s(0,20%) | ECG Output | 0.5V/m±5%;single ended≤100Ω |
| Noise Level | ≤15mVp-p | Safety Level | Class1,Type CF |
| Frequency Response | 0.05~150Hz(-3dB) | Power Requirements | AC:220V,50Hz/110V,60Hz |
| CMRR | ≥100dB | Package | 760x550x450mm(4sets);240x450x370mm(1set) |
| Sampling Rate | 1ms | Weight | 3.5kg |
Standard Accessory
Patient Cable:1pc
Paper shaft:1pc
Limb Electrode:4pcs/set
Recording paper:1 roll
Chest Electrodes:6pcs/set
Fuse:3pcsPower Cable:1pc
Built in Battery:1pc
Ground Cable:1pc
Operation Manual:1 copy